FREE U.S. SHIPPING FOR ALL ORDERS

FREE EXPRESS SHIPPING ON ALL ORDERS OVER $499

EASY 60 DAYS RETURNS POLICY Learn More>


GDT Implants EVA Mount-less Implant, Internal Hex

$75.90
SKU: E3508  |  gdtimplants-logo
Diameter \Length Ø3.5mmØ3.8mmØ4.2mmØ4.5mmØ5.0mm
8.0mm
10.0mm
11.5mm
13.0mm
16.0mm
Quantity: 0 Total: $0.00

Secure Checkout With
60 Days Money-back Guarantee

If your purchase doesn't meet your expectations, feel free to request a return within 60 days of receiving it.

Read More

Delivery and Shipping
U.S. DOMESTIC
Shipping Carriers Shipping Cost Estimated
Delivery Time
USPS Ground Free 7-15 Business days
UPS® Ground $15
(Free on Orders
Over $299)
7-10 Business days
UPS® Priority $30
(Free on Orders
Over $499)
3-5 Business days
FedEx Express Saver® $30
(Free on Orders
Over $499)
3-5 Business days

 

INTERNATIONAL SHIPPING
Shipping Carriers Shipping Cost Estimated
Delivery Time
USPS First Class Package International $20
(Free on Orders
Over $199)
7-21 Business days
UPS Worldwide Expedited® $45
(Free on Orders
Over $499)
3-4 Business days
DHL Worldwide $45
(Free on Orders
Over $499)
2-3 Business days
Read More

Why dentists choose us?

● 60 day money-back guarantee

● Up to 10% off retail prices

● Free Shipping on all orders

● 5,000+ products available

Don't want to miss out?

Join our community of dental professionals to receive updates
on exclusive deals

  • Connection: Internal Hex 2.42mm
  • Implant Diameters: 3.5mm, 3.8mm, 4.2mm, 4.5mm, 5.0mm
  • Implant Length: 8.0mm, 10.0mm, 11.5mm, 13.0mm and 16.0mm
  • Condition: Sterilized, Double Packaging
  • Material: Titanium grade 5 (TI-6AL-4V ELI)
  • Surface Treatment: RBM - Resorbable Blast Media, Calcium Phosphate.
  • Country of Manufacture: Israel 
  • Compatible Drivers:  Hex Driver and Motor Mount For Mountless Implants

The GDT EVA Implant is securely stabilized within a sterile titanium tube inside the packaging, ensuring a friction fit that allows for quick and easy driver insertion. The implant can be firmly picked up from the box and placed at the implantation site easily. After insertion, the driver can be removed. To ensure a seamless procedure during retrieval, installation, and restoration, we advise using the GDT mount-less driver. 

The GDT EVA Implant's reverse-tapered neck and platform switch are designed to optimize the amount of soft tissue and bone. Its accurate threading, annular microgrooves, and microthread design, combined with its cylindrical-conical shape, guarantee superior performance and longevity.

Furthermore, GDT EVA offers a new range of diameter options to meet a variety of clinical demands. The implant features a symmetrical double-lead thread design, which improves stability and load distribution while simplifying installation without compromising efficacy. The expanding blades at the base enable self-tapping and sealing for a snug fit. This novel feature reduces the possibility of micromotion, promotes reliable osseointegration, and ensures maximum stability for long-term success.



GDT implants are expertly made from the Titanium alloy Ti-6Al-4V ELI, renowned for its exceptional qualities. This alloy stands out for its outstanding overall biocompatibility, low specific weight, high strength-to-weight ratio, and remarkable corrosion resistance.

Distinguished by its similarity to Ti-6Al-4V, Ti-6Al-4V ELI sets itself apart through reduced levels of oxygen, nitrogen, carbon, and iron. The designation "Extra Low Interstitials" (ELI) contributes to enhanced fracture toughness and ductility in the material.

The effectiveness of Ti-6Al-4V ELI is exemplified in the realm of dental implants, showcasing its reliability and suitability for crucial applications. GDT implants, constructed from this cutting-edge alloy, deliver optimal performance in dental implantation procedures by combining strength, durability, and biocompatibility.

RBM Surface Treatment Technology:

RBM surface is rough and hydrophilic. 
This surface treatment is designed to roughen the implant surface without leaving the residual embedded blast particles or debris in the treated substrate. 
To gain the desired roughening the implant is blasted with suitable hardened particles of Hydroxyapatite (beta-tricalcium Phosphate, Alpha Tcp, TTcp, and Calcium Phosphate (CPP) and then subsequently dissolved from the surface with a defined passivation treatment.
Surface roughness between Ra 1.2 - 1.5 is consistently achieved.
The result is a rougher implant surface than traditional acid etches treatment providing a greater surface area for osseointegration, improved retention characteristics, increased biological fixation, and maximizing implant-to-bone contact.

The shape of the implant is made for simple and secure work and improving the osseointegration level. 
The RBM surface treatment is made to improve the healing process and tissue growth around the implant, with no worries of abruption or disintegration.


Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Your cart
0 items

Your cart is empty

Gdt Implants Eva Mount-Less Implant Internal Hex Dental
gdtimplants
GDT Implants EVA Mount-less Implant, Internal Hex
$75.90
  • Connection: Internal Hex 2.42mm
  • Implant Diameters: 3.5mm, 3.8mm, 4.2mm, 4.5mm, 5.0mm
  • Implant Length: 8.0mm, 10.0mm, 11.5mm, 13.0mm and 16.0mm
  • Condition: Sterilized, Double Packaging
  • Material: Titanium grade 5 (TI-6AL-4V ELI)
  • Surface Treatment: RBM - Resorbable Blast Media, Calcium Phosphate.
  • Country of Manufacture: Israel 
  • Compatible Drivers:  Hex Driver and Motor Mount For Mountless Implants

The GDT EVA Implant is securely stabilized within a sterile titanium tube inside the packaging, ensuring a friction fit that allows for quick and easy driver insertion. The implant can be firmly picked up from the box and placed at the implantation site easily. After insertion, the driver can be removed. To ensure a seamless procedure during retrieval, installation, and restoration, we advise using the GDT mount-less driver. 

The GDT EVA Implant's reverse-tapered neck and platform switch are designed to optimize the amount of soft tissue and bone. Its accurate threading, annular microgrooves, and microthread design, combined with its cylindrical-conical shape, guarantee superior performance and longevity.

Furthermore, GDT EVA offers a new range of diameter options to meet a variety of clinical demands. The implant features a symmetrical double-lead thread design, which improves stability and load distribution while simplifying installation without compromising efficacy. The expanding blades at the base enable self-tapping and sealing for a snug fit. This novel feature reduces the possibility of micromotion, promotes reliable osseointegration, and ensures maximum stability for long-term success.



GDT implants are expertly made from the Titanium alloy Ti-6Al-4V ELI, renowned for its exceptional qualities. This alloy stands out for its outstanding overall biocompatibility, low specific weight, high strength-to-weight ratio, and remarkable corrosion resistance.

Distinguished by its similarity to Ti-6Al-4V, Ti-6Al-4V ELI sets itself apart through reduced levels of oxygen, nitrogen, carbon, and iron. The designation "Extra Low Interstitials" (ELI) contributes to enhanced fracture toughness and ductility in the material.

The effectiveness of Ti-6Al-4V ELI is exemplified in the realm of dental implants, showcasing its reliability and suitability for crucial applications. GDT implants, constructed from this cutting-edge alloy, deliver optimal performance in dental implantation procedures by combining strength, durability, and biocompatibility.

RBM Surface Treatment Technology:

RBM surface is rough and hydrophilic. 
This surface treatment is designed to roughen the implant surface without leaving the residual embedded blast particles or debris in the treated substrate. 
To gain the desired roughening the implant is blasted with suitable hardened particles of Hydroxyapatite (beta-tricalcium Phosphate, Alpha Tcp, TTcp, and Calcium Phosphate (CPP) and then subsequently dissolved from the surface with a defined passivation treatment.
Surface roughness between Ra 1.2 - 1.5 is consistently achieved.
The result is a rougher implant surface than traditional acid etches treatment providing a greater surface area for osseointegration, improved retention characteristics, increased biological fixation, and maximizing implant-to-bone contact.

The shape of the implant is made for simple and secure work and improving the osseointegration level. 
The RBM surface treatment is made to improve the healing process and tissue growth around the implant, with no worries of abruption or disintegration.


Diameter

  • Ø3.5mm
  • Ø3.8mm
  • Ø4.2mm
  • Ø4.5mm
  • Ø5.0mm

Length

  • 8.0mm
  • 10.0mm
  • 11.5mm
  • 13.0mm
  • 16.0mm
View product